Trunk

Supine Trunk Flexion: Range of Motion Assessment

A 3D product render of the blue Kinvent K-Move motion sensor device isolated on a transparent background, displaying its compact casing, logo, orange power button, and charging port
Definition

The Supine Abdominal / Trunk Flexion (ROM) Test using an electrogoniometer (K-Move) quantifies the maximum active angular displacement of the upper trunk (thoracic and upper lumbar spine) as the individual performs a curl-up or abdominal flexion movement. This test assesses the flexibility and active range of the spinal flexors and anterior abdominal wall musculature. It is used in clinical settings and fitness assessments to evaluate spinal mobility in flexion, identify limitations, monitor progress of rehabilitation or exercise programs, and in ergonomic or biomechanical research. If using a single K-Move sensor on the trunk, careful observation to minimize pelvic movement is essential for interpreting the data as primarily trunk flexion.

Purpose

To objectively measure the active range of motion of the thoracic and upper lumbar spine during a standardized abdominal curl-up, providing a quantitative baseline for trunk flexion mobility.

Required Tools

K-Move

Steps

Ensure the K-Move electrogoniometer sensor(s) are charged and functioning correctly. K-Move sensor is strap-based.

Patient Positioning: The patient lies supine (on their back) on a firm examination bed or mat.

Knees are bent to approximately 70-90 degrees, with feet flat on the bed/mat, about hip-width apart. This position helps to stabilize the pelvis and reduce the involvement of hip flexor muscles. Arm Position: Standardize arm position as it significantly affects the difficulty and ROM of a curl-up.

Sensor Placement (K-Move or similar electrogoniometer): A K-Move sensor is typically placed on the sternum (e.g., at the level of the manubrium or mid-sternum) or along the upper thoracic spine. It should be aligned longitudinally with the trunk. This sensor will measure the angular displacement of the upper trunk relative to the horizontal or its starting position.

Calibration/Zeroing: With the patient lying supine in the standardized starting position (knees bent, arms in chosen position, head resting), calibrate or “zero” the K-Move electrogoniometer according to the device’s instructions. This establishes the baseline (0 degrees) from which the trunk flexion angle will be measured.

Movement Execution: Instruct the patient on active trunk flexion (curl-up): “Slowly curl your head and upper body upwards, bringing your chest towards your knees, as far as you comfortably can. Keep your lower back pressed into the mat initially, and try not to lift your feet.” The extent of the curl-up should be standardized if possible (e.g., “curl up until your shoulder blades just leave the mat,” or “curl up as far as you can without your feet lifting or significant discomfort”). The movement should be smooth and controlled, focusing on flexing the spine using abdominal muscles. Avoid jerking or using momentum.

Examiner’s Role: Carefully observe that the pelvis remains relatively stable (minimal posterior tilt) and that the feet do not lift off the surface, which would indicate excessive hip flexor recruitment or insufficient abdominal control for pure trunk flexion. The K-Move electrogoniometer will display and/or record the peak angular displacement of the trunk sensor from its zeroed start position. This is the Trunk Flexion ROM.

Configuration
Preparation
3 sec
Repetitions
3 repetitions
Rest Time
3 sec
Duration
5 sec
Instructions for the Patient

We are going to measure how far you can curl your upper body up. I will be placing this sensor [show K-Move sensor] on your chest/upper back. Please lie on your back with your knees bent and your feet flat on the [bed/mat], about hip-width apart. Please cross your arms over your chest with your hands on your shoulders [or other standardized arm position]. Let your head rest back. This is your starting position. [Perform calibration/zeroing of the device]. Now, when I ask you to, I want you to slowly tuck your chin slightly and curl your head, shoulders, and upper back off the [bed/mat], bringing your chest towards your knees. Go as far as you comfortably can [or specify endpoint like ‘until your shoulder blades lift off’]. Try to keep your lower back on the mat for as long as possible and your feet flat. Then slowly uncurl back to the starting position. Please move smoothly and avoid any quick or jerky movements. Let me know if you feel any discomfort. Are you ready? Okay, please slowly curl up… as far as is comfortable… And now slowly uncurl back down. We will do this [2 or 3] times.

Key Results

Maximum Flexion Angle (°): The peak angular displacement achieved during the curl-up movement, representing the maximum active range of motion.

Flexion Angular Velocity (°/s): The peak speed of the trunk’s movement into flexion, indicating the dynamic control and speed of contraction.

Validity References

Norkin, C. C., & White, D. J. (2016). Measurement of Joint Motion: A Guide to Goniometry (5th ed.). F.A. Davis Company.

Tousignant, M., Poulin, N., Marchand, S., Viau, A., & Place, C. (2006). The Mobile Tensiomyography System (MTMS): A new tool for the in-vivo assessment of skeletal muscle mechanical properties. Journal of Electromyography and Kinesiology, 16(4), 371-380.

Clinical Practice References

Lee, R. Y., & Wong, T. K. (2002). Relationship between C7-T12 and T12-S1 sagittal spinal curves and trunk extension in healthy adults. Journal of Manipulative and Physiological Therapeutics, 25(3), 163-168.

CONTINUE IN KINVENT

Start the activity

Run this protocol in the Kinvent app with your compatible equipment.

UNDERSTANDING THE TEST

Questions & answers

How should I interpret a change in range of motion at a follow-up visit?

Start by confirming that the two assessments used the same sensor position, zeroing procedure, arm position and curl-up endpoint. Compare the repetitions as well as the session summary. A larger angle is more useful when it appears across comparable attempts and the movement observations support the comparison.

For example, an increase recorded after changing from arms crossed over the chest to arms reaching forward cannot be attributed confidently to improved mobility alone. Document the change in conditions and, where appropriate, establish a new baseline using the revised setup.

Record the angle, any available angular-velocity result, the endpoint reached, symptoms and notable movement changes. If you use a reference range or a threshold for meaningful change, it should come from evidence matching this task, measurement method and patient population; a generic standing-flexion value is not an appropriate substitute.

A difference of a few degrees should not automatically be labelled recovery or deterioration. Interpret it alongside repeatability, symptoms and function, especially when no applicable measurement-error threshold is available.

How is this different from standing trunk flexion or an abdominal strength test?

Choose the assessment according to the question you need to answer. Although all three involve the trunk, they do not measure the same task or produce interchangeable results.

Supine abdominal range of motion: the person performs an active curl-up from lying. The main result is the angular movement of the upper trunk from its zeroed starting position.

Standing trunk flexion: the person bends forward from standing. The starting posture and movement task differ, so a degree value from that assessment should not be used as the target for this curl-up.

Supine trunk-flexion strength: the person produces force during an isometric assessment. This addresses force production rather than the range achieved during a moving curl-up.

For example, reaching further during a curl-up does not demonstrate an increase in maximum abdominal force. Conversely, a strength result cannot tell you how much active curl-up range is available. When both mobility and strength matter, record them as separate assessments and keep their conclusions separate in the report.

What should I check if the flexion angle is low or the movement looks uneven?

First establish whether the reading reflects the movement you intended to measure. Check that the sensor has not slipped, that it was zeroed before the curl-up, and that the person understood the endpoint. Then look at the performance: did the feet lift, did the pelvis move substantially, did the arm position change, or did the person stop because of discomfort? Record the reason for stopping rather than treating every limited attempt as the same finding.

If the setup was inconsistent, correct it before deciding whether a repeat is appropriate. If discomfort limited the movement, do not encourage the person to push further just to improve the number; the clinician should assess the symptoms and decide how to proceed.

A low angle alone does not establish abdominal weakness or identify a spinal condition. Likewise, this single-plane flexion test does not provide a left–right asymmetry percentage. If one shoulder rises before the other or the trunk visibly rotates, document that observation separately and investigate it with an assessment suited to that question.

How can I make curl-up measurements repeatable?

Standardize the starting position and the movement endpoint before collecting the first result. A small change in the instructions can change what the angle represents, even when the same sensor is used.

Position: use the same firm surface, knees bent approximately 70–90 degrees, feet flat and about hip-width apart. Choose one arm position and retain it throughout the assessment and follow-up visits.

Sensor: use the same documented location on the sternum or upper thoracic spine, aligned with the trunk. Check that the attachment remains secure.

Starting angle: zero K-Move with the person settled in the agreed starting position, before they lift their head or shoulders.

Endpoint: specify one consistent endpoint, such as the shoulder blades leaving the mat or the maximum comfortable curl-up. Do not alternate between those instructions when comparing results.

Movement: ask for a smooth curl-up and return. Observe the feet and pelvis, and note any change in technique or discomfort.

The configuration above uses three repetitions. Keep the individual trial results and movement observations so an unusually large or small reading can be checked against what happened during that repetition.

What does the abdominals range-of-motion test actually measure?

The test measures how far the upper trunk moves from a defined starting position during an active curl-up. With the person lying on their back, K-Move is zeroed on the upper trunk before the movement begins. The maximum flexion angle, expressed in degrees, describes the greatest angular displacement reached. Angular velocity, expressed in degrees per second, describes how quickly that movement occurs. These are different outcomes: a faster repetition does not necessarily reach a greater range.

The abdominal muscles help produce the movement, but the angle is not a measurement of their maximum strength. A person can achieve a similar angle using a different speed or movement strategy. With one sensor on the trunk, pelvic movement also needs to be observed; the reading should not be treated as an isolated measurement of each spinal segment.

Use this assessment to describe active curl-up mobility and follow its evolution under consistent conditions. If the clinical question concerns maximum abdominal force, choose a dedicated strength assessment instead.

Read more: K-Move: motion and range-of-motion measurement